TA134 - Tachometer electronic
Product selection
Interface
Outputs
Voltage supply

TA134.###AX01
Technical data - electrical ratings
Voltage supply 22...50 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
12...30 VDC
Power consumption 5 VA
5 W
Sensor supply AC: 24 VDC ±20 % / 100 mA
DC: 9...28 VDC / 100 mA
Display LCD, 7-segment display,
2-lines, backlit
Number of digits 6-digits
Digit height 7 mm
4 mm (count)
Unit displayed 1/s, 1/min, 1/h programmable
Function Tachometer
Measuring principle Period duration measurement
Signal inputs Comparator inputs
Input logic NPN / PNP
Control inputs 3 programmable
Control functions Stop, Hold, Print
Counting frequency 3 Hz, 25 Hz, 10 kHz programmable
Tacho frequency 25 Hz, 40 kHz programmable
Scaling factor 0.0001...9999.99
Data memory >10 years in EEPROM
Outputs electronic Optocoupler
Outputs relay Normally open or closed, programmable
Interface RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference DIN EN 61000-6-4
Interference immunity DIN EN 61000-6-2
Programmable
parameters
Measuring units 1/h, 1/min, 1/s
Scaling factor
Sensor logic
Control inputs
Count frequency
Approval UL approval / E63076
 
Technical data - mechanical design
Operating temperature 0...+50 Â°C
Storing temperature -20...+70 Â°C
Relative humidity 80 % non-condensing
Connection Plug-in screw terminals
Core cross-section 1.5 mm²
Protection DIN EN 60529 IP 65 face with seal
Operation / keypad Membrane with softkeys
Housing type Housing for control panel installation
Dimensions W x H x L 48 x 48 x 100 mm
Cutout dimensions 45 x 45 mm (+0.6)
Installation depth 100 mm
Mounting Front panel installation by clip frame
Weight approx. 150 g
Material Housing: Makrolon 6485 (PC)