Technical data - electrical ratings
| Voltage supply |
22...50 VAC (50/60 Hz) 85...265 VAC (50/60 Hz) 12...30 VDC |
| Power consumption |
5 VA 5 W |
| Sensor supply |
AC: 24 VDC ±20 % / 100 mA DC: 9...28 VDC / 100 mA |
| Display |
LCD, 7-segment display, 2-lines, backlit |
| Number of digits |
6-digits 8-digits - totalizer in 2 steps |
| Digit height |
7 mm 4 mm (count) |
| Function |
Hour counter Main counter with 2 presets |
| Count mode |
Adding or subtracting |
| Counting frequency |
Batch counter: approx. 20 Hz |
| Operating mode |
Time meter and hour counter |
| Data memory |
>10 years in EEPROM |
| Reset |
Button, electric or automatic |
| Keylock |
Yes, electric (keylock) |
| Outputs electronic |
Optocoupler |
| Outputs relay |
Normally open or closed, programmable |
| Output holding time |
0.01...99.99 s |
| Interface |
RS485 |
Standard DIN EN 61010‑1 |
Protection class II Overvoltage category II Pollution degree 2 |
| Emitted interference |
DIN EN 61000-6-4 |
| Interference immunity |
DIN EN 61000-6-2 |
Programmable parameters |
Measuring units, sensor logic Control inputs |
| Approval |
UL approval / E63076 |
| |
Technical data - mechanical design
| Operating temperature |
0...+50 °C |
| Storing temperature |
-20...+70 °C |
| Relative humidity |
80 % non-condensing |
| Connection |
Plug-in screw terminals |
| Core cross-section |
1.5 mm² |
| Protection DIN EN 60529 |
IP 65 face with seal |
| Operation / keypad |
Membrane with softkeys |
| Housing type |
Built-in housing |
| Dimensions W x H x L |
48 x 48 x 100 mm |
| Installation depth |
100 mm |
| Mounting |
Clip frame |
| Cutout dimensions |
45 x 45 mm (+0.6) |
| Materials |
Housing: Makrolon 6485 (PC) Keypad: Polyester |
| Weight approx. |
150 g |
|